RF Remanufactured

GE-RFX-Package-CMXWestern Diagnostic’s remanufactured GE RFX systems begin with a complete tear-down. All mechanical and electronic systems are then functionally and cosmetically inspected, evaluated and remanufactured to exacting standards. After a detailed three-step paint process, each system is pre-staged for operational compatibility and calibration to OEM specifications.

Bundled with a NEW high frequency X-ray generator from CPI and an array of powerful imaging options, this versatile suite offers excellent imaging at an affordable price.

Features

Table Features:

  • Quiet angulation drive with soft start and stop feature.
  • Tabletop longitudinal drive interlocked with angulation drive to prevent collision with floor and ceiling.
  • Tabletop and footrest extend downward toward floor with table vertical.

Range of Motion:

  • 73.5” (187 cm) fluoroscopic beam center-to-floor dimensions when table is vertical for cervical esophagus coverage on 6′ 8” (2.0 m) tall patients.
  • 11” (28 cm) transverse fluoroscopic carriage travel.
  • 20” (50 cm) maximum caliper opening between bottom of spotfilmer or pedestal and tabletop. 19” (48 cm) maximum with 4-way flat top.
  • Structural plastic front and end panels shaped to eliminate sharp edges and barium traps while resisting strains, dents and corrosion.
  • Undertable X-ray tube equipped with a forced oil/ air heat exchanger for improved cooling.

Convenient Operator Features:

  • All table controls needed by technologist are located conveniently on table.
  • Interlocked patient step eliminates need for accessory foot stool.
  • Patient hand grips may be quickly attached at any point on front or rear of tabletop.

Myelographic Stop:

  • When automatic stop at horizontal is defeated for myelography and other needle intensive procedures, the compression cone drive is disabled.

Efficient Bucky Design:

  • Entrance type, three field Quantamat lonization Bucky Detector designed for minimum object film distance.
  • HGrid lines virtually invisible at 8 msec with 103-line grid.

RFX 88 Spotfilm Device:

  • Accepts 9.5” x 9.5” (24 x 24 cm) cassette sizes for operating simplicity and rapid access from fluoro mode.
  • Effort sensing, longitudinal power assist control in positioning handle.
  • 1-on-1, 2-on-1 longitudinal, 2-on-1 transverse, and 4-on-1 formats.
  • Spotfilm access time from fluoro mode is approximately 0.75 seconds.
  • Rapid-sequence spotfilms are accomplished with approximately 0.5 seconds between exposures.
  • Table Bucky “center-finder” feature.

Included Packaged Components:

  • Remanufactured GE RFX table and GE RFX 88 Spotfilm Device
  • New CPI high-frequency generator.
  • Remanufactured GE XT Suspension and GE Sentry III X-ray Collimator.
  • 9”, 6”,4.5″ I.I. (12”,14”,16” available)
  • Optional digital imaging package.

Request A Quote - CMX
(Click Image Below for Full Brochure)

RF-Remanufactured - CMX